Principles Of Hospital Design And Equipment (Part 12) -Central  supply  sterile

Principles Of Hospital Design And Equipment (Part 12) -Central  supply  sterile

Standards, heads, and introduction to other sections are provided

Position sterilization section
Central sterile central supply

Create a place to reassure the CSR department adjacent to the operating rooms. So that you can eliminate yourself separately, you can have service providers, have service providers at their disposal so that they can help you. A public corridor is provided, you can provide services to other service departments.
Position sterilization section
Central sterile central supply
CSR consists of the following three control steps:

1- Washing and disinfection
2- Tabulation
3- Sterilization of anyone who can do it in their specific area. The following is a specific description of each person who is allowed.
Dirty or washing area:
There are four training, assistant, washing, and disinfection operations based in the area. The set of services provided to you is possible so that you can use them. Air pressure in a dirty area is limited to negative cyberspace.
Clean area:
Four feasibility or collection, adjustment, control and inspection, and distribution (packing) operations are performed in this area.
Packing is done manually in a normally clean area. This area is the most dangerous part of the CSD. The air pressure of this area is limited to the other two areas and the air below the two-person section is +2 and it can be seen 10 Pascals with adjacent environments. The profile can change in this area 15 times an hour.
Autoclave devices can be extended with two separate doors on two sides. The selected log door to the internal address of the autoclave in the clean area is open and the sterilized medical door to the sterile area is renovated. Clean area You can use the lanyard to access the magazine door to log in or get dressed. This door is called a clean lounge entrance door.
Sterile area:
The outlet door of the autoclave opens to the sterile area. Sterile operations are deployed in this area or can be performed by stressing from inside the autoclaves.
From the infrastructure level, this area is limited to two other smaller areas. Delivery of sterilized services in the GTA or other departments is done through the sea, special boxes provided by two visiting doors, equipped with UV lamps.
Space is required under the CSD section:
By using the virtual location and access to the offered resources, it has provided access to advertising services and you can use different sources to provide you. Gunning (entering the gun) to enter a clean and sterile area - Health and bathroom service protection space - Warehouse and accommodation Magazine for dirty, clean, and sterile services.
CSR infrastructure:
CSR Section Infrastructure 1 ٪ This area is provided per view of 75 m2.
Technical specifications The CSR design is horseshoe-shaped or U-shaped. You can have a dirty area on one edge and a clean area at the base and a sterile area on the other edge, respectively.
Another type of design of this section is rectangular. The dirty area at the beginning and clean area in the middle and sterile area at the end, respectively. The important point is that how dirty services enter and the way out of sterilized services can necessarily be found through a scientific journal.
The roof of the section can be flat and change from other types of porous to access the entrance, neck, and visitors and access to the interior space in this section. The use of perforated false ceilings is not allowed.
The materials used in CSR can be used to succeed in biological and microorganisms using these experiences.
Washing machines can be seen in two opposite doors. Enter the wash area and exit door open in the clean area.
Autoclaves The best available condition of two reciprocating doors. Enter the clean area site and return the exit door in the sterile area.
Services to help you move services to the CSR department and vice versa, forklifts, necessarily have higher services if they can provide their services in summary. Lifting service provider services
The laundry service shop in Lingerie is returned to the clean area after a pre-presentation.
It is necessary to watch the clean area with 15 air changes, 12 times for the sterile area, and 5 times for the washing area.
The lights used in the CSR section and the permissible limit for eye control can be removed and provided to you.
To provide specialized services for all vehicles and rice capability, you can necessarily be equipped to upgrade the system and protect resources. The upgrade system is necessary to achieve access to it, as regular monitoring.
To receive air interference, you may be provided with an air lockbox for the delivery of sterilized services.
If you observe gas autoclave, the ethylene theory of representation in the CSR section tells you that it has a security system and can predict for these autoclaves.